AD-4712
A and A Scales LLC
"We will not be undersold"
Open 7 days a week

Toll free 800-481-4114
Local     973-800-3965
Home

e-mail
Have you seen a lower price? Click here to let us know

Contact US/Request for quote          Click here to order online

 

Farm/ Cattle/ Horse Livestock Scales

 

Paul Livestock
Scales

 

Portable Truck Scales

 

 


A&D Scales

Click here for 

A&D balances

 

Click here for 

A&D scales

 

 

Transcell Technology
Scales / load cells


Avery Berkel
Scales



Money Scales

 

Label printing scale

Label Printing Scales
from $995

 

 

Products

Pallet_Scales 

Legal for Trade scales

Used Scales

Lab Balances

Bench Scales

Stainless Bench Scales

Stainless Checkweighers

Stainless Portion Scales

Counting Scales

Crane Scales

Floor / Drum Scales

Fork Lift Scales

Indicators

Junction Boxes

Livestock Scales

Load Cells

Mechanical Scales

Money Counting Scales

Postal Scales

Price Computing/Deli

Printers

Remote Displays

Shipping Scales

Truck Scales

Health/Physician/Baby


 

                               AD-4712            AD-4714A              AD-4715

Please click on a picture for a closer view

 

Features (AD-4712)

No need to measure sample weight, use any amount between 5 and 70 grams (0.18~2.47oz.)
High efficiency sheathed ceramic heater reduces measurement error normally caused by uneven heating or burning of a sample.
Non-volatile memory preserves temperature and time setting even after the unit is turned off.
Uses an automatic pan lifting mechanism, the Auto-Tare function compensates for zero drift during drying.
Auto stop mode eliminates the need to manually monitor the operation.

Fast mode speeds up analysis process by initially increasing the temperature of the heating element .

 

Features (AD-4714A)

No need to measure sample weight, use any amount between 5 and 70 grams (0.18~2.47 oz).
Easy-to-use: simply load a sample and press the START key.
Heating lamp shuts off automatically if the maximum temperature setting (200°C / 392°F) is reached.
Operator can use the same key to digitally set both time & temperature.

Features (AD-4715)

Moisture Determination accuracy to 0.01%.
Non-volatile memory preserves temperature and time settings after the unit is turned off.
Alarm sounds at the end of the drying period.
Standard RS-232 allows interface with computer or DPU-411 Printer.
Wide Angle, Multi-Information LCD Display enhances operating capability & provides thorough & immediate feedback to the operator.
Moisture Content Predict Mode speeds accuracy & operation in only 5 minutes.
Full Digital Calibration simplifies calibration process through push button calibration.

 

Moisture Balance Specifications

 

AD-4712

AD-4714A

AD-4715

Measurement Method

Infrared radiation & detection of weight loss

Sample Weight Range

5 ~ 70g / 0.18 ~ 2.47 oz

5 ~ 70g / 0.18 ~ 2.47 oz

1 ~ 300g / 0.04 ~ 10.58 oz

Weight Readability

0.01g

0.01g

0.001g

Water Content

0~ 100%(wet base)

0~ 100%(wet base)

0~ 100%(wet base)

Measurement Range

0~ 500%(dry base)

 

0~ 500%(dry base)

 

0~ 100%(solid base)

 

0~ 100%(solid base)

Water Content Readability

0.1%

0.1%

0.01% / 0.1%

Water Content

± 0.1% (20 ~ 70g)

± 0.1% (10 ~ 70g)

± 0.1% (over 3g)

Accuracy Measurement

± 0.2% (5 ~ 20g)

± 0.2% (5 ~ 10g)

± 0.2% (1 ~ 3g)

 

Digital LCD

Digital LCD

Digital LCD

Display

Moisture Content (%)

Moisture Content (%)

Moisture Content (%)

 

Temperature ºC

Temperature ºC

Temperature ºC

 

Time (min), Weight (g)

Time (min), Weight (g)

Time (min), Weight (g)

     

Time & Date, Mode

Elasped Time

Drying Temperature

50 ~ 400°C / 122 ~ 784°F

50 ~ 180°C / 122 ~ 356°F

40 ~ 200ºC / 104 ~ 392°F

Time setting

1~ 90 min or continuous

1~ 99 min or continuous

1~ 990 min of continuous

 

Auto-Stop

Auto-Stop

Automatic Predict

Weighing Pan Diameter

Æ 120 mm / 4.7 in.

Æ 95 mm / 3.7 in.

Æ 130 mm / 5.1 in.

Temperature Control Method

PID thermostatic control Platinum sensor

PID thermostatic control Thermistor sensor

PID thermostatic control Thermistor sensor

Heater

280W Sheathed Ceramic Heater

185W Infrared Lamp

400W Infrared Lamp

Data Output

Optional serial interface FXY-03

Not available

Std. serial interface

Printer

AD-8121A

Not available

DPU-411

External Control

Not available

Not available

Std. remote control keyboard

Power (factory installed)

100, 120, 220, 240 VAC

100, 120, 220, 240 VAC

100, 120, 220, 240 VAC

Weight

4.9 kg / 10.3 lb

3.0 kg / 6.6 lb

5.4 kg / 11.9 lb

Dimensions (mm)

195(W) x 315(D) x170(H)

210(W) x 320(D) x 318 (H)

194(W)x 319(D) x 331(H)

Dimensions (inch)

7.7(W) x 12.4(D) x 6.7(H)

8.3(W) x 12.6(D) x 12.5(H)

7.6(W) x 12.6(D) x 13.0(H)

Standard Accessories

Spoon, Tweezers, Pan Foils, Manual, Dust Cover

Accessories

ET:SHEET-AD4712

(Pan foils 25 pcs)

ET:SHEET-AD4714

(Pan foils 10 pcs)

ET:SHEET-AD4715

(Pan foils 20 pcs)

 

FXY-03 RS-232C / Current Loop Interface

ET-IR185W-120V

(120V Lamp)

ET-IR400W-120V

(120V Lamp)

   

ET:IR185W-220V

(220V Lamp)

ET:IR400W-220V

(220V Lamp)

Specifications are subject to change for improvement without notice

Model Part # List Price
AD-4712 70g x 0.01g 13251 $3,095
AD-4712-2 (240V) 70g x 0.01g 13252 $3,195
     
AD-4714A 70g x 0.01g 13254 $2,450
AD-4715 300g x 0.001g 13253 $5,295

Specifications and prices are subject to change

 


Sensortronics
load cells

Scaime
load cells

Revere
Transducer

Load cells

BLH
load cells

Click below to Translate our website into Spanish, Chinese, French, German, Italian, Japanese, Korean or Portuguese.

Click Here for translation

 

E-mail

A and A Scales LLC

78 North 12th Street

Prospect Park NJ 07508

Phone 800-481-4114  973-956-1600

Fax    509-355-3498

We accept Visa, Mastercard & AMEX. Net 30 payment terms for qualified buyers
Legal Disclaimer & Return Policy